Analyzer Characteristics
LD300L is based on the forward light scattering principle, adopts a patented extraction and heating return method, and the optional isokinetic tracking module adopts an adaptive binning method, which can be used for a wide range of particle concentration measurement, especially suitable for ultra-low range, high measurement target Continuous measurement under humidity and condensation conditions. It can be widely used in places where two-phase flow particles are continuously measured, such as flue gas emission, process control, health, safety, scientific research, etc.
Technical characteristics
◎The patented forward scattering principle based on soot particles has extremely high sensitivity and resolution, and can continuously measure the emission of ultra-low concentrations of soot particles online.
◎Patented unique extraction heating and return method, which can be used in occasions where the measured gas contains extremely high water mist.
◎Equipped with optional isokinetic sampling module for isokinetic tracking sampling and testing.
◎The adaptive dynamic classification method can measure very low concentrations of smoke and dust particles, and can also measure very high concentrations of smoke and dust. It has an extremely wide dynamic range.
◎Patented automatic zero point and automatic span calibration.
Project | Indicators |
Measuring Range | 0.01-20 mg/m3 ,0.01-200g/m 3 (can be customized) |
measurement Error | ≤1.5%F.S./week |
Zero and span drift | ≤1.5%F.S./week |
Indication error | ±20% |
Resolution ratio | Better than 0.005mg/m3 |
Signal output | (4-20)mA,RS485 |
Flue pipe diameter | (0.3-20) m |
Condition of measured medium | 0-300℃ |
Backblowing requirements | 100L/min, clean, Pressure 2KG/cm2 |
Protection level | IP65 |
Power supply | 220±15%(VAC),600W |
Dust analyzer Size | 410mm*300mm*140mm |
Dust analyzer Weight | 15KG |