• Professional CEMS TDLAS VOCs Manufacturer
  • +86 18255177197
  • ez@zuoyeal.com

    ZUOYEALLOGOZUOYEALLOGOZUOYEALLOGOZUOYEALLOGO

    • Home
    • About Us
      • Video
      • FAQ
      • Download
    • Products
      • Stack Emission
        • CEMS
        • VOCs
        • NDIR System
        • Laser Analyzer
      • Water Environment
      • Ambient Air
      • Process Accessories
    • News
    • Contact Us
    Get a Quote

      captcha

      • Home
      • Products
      • Ambient Air
      • ZY-AQMS200 PM2.5 PM10 β-Ray Particulate Matter Monitor
      Show all

      ZY-AQMS200 PM2.5 PM10 β-Ray Particulate Matter Monitor

      Category: Ambient Air

      The AQMS β-ray particle monitor uses β-rays, uses low-energy C14 as the source of β-rays, and calculates the mass of the particles collected on the filter paper according to the amount of change when the B-rays pass through the clean filter paper and the filter paper with particles collected. Find the concentration of particulate matter in the air.

      mail ez@zuoyeal.com
      GET A QUOTE

        captcha

        WHATSAPP
        Share

        Detail Description

        It is widely used to measure the concentration of particulate matter in ambient air, such as PM10, PM2.5 (optional different sampling and cutting heads), etc. The overall design of the instrument is reasonable, beautiful, easy to use and easy to maintain.

        Technical characteristics

        ◎Modular design, low failure rate, easy maintenance, strong expansibility;

        ◎Intelligent design, with fault alarm and fault self-diagnosis function;

        ◎Different cutter heads can be selected for real-time measurement of PM10 and PM2.5 concentrations;

        ◎The β-ray absorption method is used to directly measure the mass concentration of particulate matter, which is not affected by seasonal changes; accurate data is provided in real time around the clock without correction;

        ◎The instrument adopts the same position detection method of sampling and detection, which fundamentally solves the measurement error caused by moving the paper tape;

        ◎DHS (Dynamic Heating System) is used to heat the sampling inlet gas and has the function of dynamic temperature and humidity compensation, which conforms to national standards and can ensure accurate measurement of semi-volatile nitrates and organic compounds;

        ◎Adopt imported detector, stable measurement, safe and reliable, accurate data;

        ◎The sampling data is automatically memorized, the current data is automatically saved after a power failure, and the instrument can continue to sample after the power is turned on;

        ◎Support multiple methods of data remote transmission, including: WIFI, ZigBee, 3G, 4G, ADSL, optical fiber, etc.;

        ◎Stainless steel material, can adapt to all-weather complex environment, with electronic compatible design, as well as dust-proof and waterproof design;

        ◎A large amount of data storage capacity, can store up to 365 days of data volume.

        Parameter Indicators
        Measurement range 0-1,000ug/m3
        β ray source C-14, Half-life 5730 years
        Sampling flow 16.7 L/min,precision ±2.5%
        Calibration method Standard membrane calibration
        Detection limit 2μg/m³
        Resolution 0.1μg/m³
        Atmospheric pressure detection (30~130)kPa
        Calibration membrane reproduction ≤2% nominal value
        Linear regression (0±10)μg/m3
        Correlation coefficient ≥0.93
        Dynamic heating (DHS) (0-60) ℃ can be set
        Humidity detection (0-99) % RH can be set
        Air intake heating Permanent dynamic heating, automatic temperature and humidity compensation
        Temperature Range: – 50 ~ 100 ℃

        Resolution: 0.1 ℃

        Accuracy: ± 0.5 ℃

        Humidity Range: 0~100%RH

        Resolution: 0.1 %RH

        Accuracy: ± 3 %RH

        Wind speed Range: 0~70m/s

        Resolution: 0.1 m/s

        Start wind speed: ≥0.5m/s

        Accuracy: ± 0.3 m/s

        Wind direction Range: 0-360°

        Resolution: 0.1°

        Start wind speed: ≥0.5m/s

        Accuracy: ± 3 °

        Atmospheric pressure Range: 10~1100hpa

        Resolution: 0.1 hpa

        Accuracy: ± 0.5hpa

        Noise Frequency response: 16 ~ 20kHz

        Measurement range: 30 ~ 140db

        Frequency Equipment: A, C, Z

         

        Product Enquiry

        Enquire about ZY-AQMS200 PM2.5 PM10 β-Ray Particulate Matter Monitor

          captcha

          Related Products

          2022-08-26

          ZY-AQMS100 Micro Ambient Air Quality Monitoring System


          2021-08-04

          AQMS2000 Air Quality Monitoring System


          Product Catagory

          • Stack Emission
            • CEMS
            • VOCs
            • NDIR System
            • Laser Analyzer
            • Dust analyzer
          • Process Accessories
          • Water Environment
          • Ambient Air
          • Gas detector

          Product Tags

          CEMS (1)

          GET IN TOUCH WITH US!

          Get A Quote

            captcha

            Professional Supplier of Analyzer With International Vision And International Standard

            NANJING ZUOYEAL TECHNOLOGY CO,.LTD
            Room 603, No.118, Central Road, Baguazhou street, Qixia District, Nanjing, China.
            ez@zuoyeal.com / ezrealniu@gmail.com
            +86-18255177197

            Send Us Message


              captcha

              Recent Posts

              • What is the difference between the VOCs and the CEMS? 2021-08-13
              • VOCs emission control requirements 2021-08-13
              • What are the system components of the VOC online monitoring system? 2021-08-13
              © 2019 ZUOYEAL. All Rights Reserved. 左仪